Technical Specifications
Air Pressure
Range/Resolution/Accuracy  ± 4000 Pascals / 1 Pascal / ± 1 % + 1 Pascal

 ± 16 in H2O / 0.001 in H2O / ± 1 % + 0.01 in H2O

 ± 400 mm H2O / 0.1 mm H2O / ± 1 % + 0.1 mm H2O

 ± 40 mbar / 0.01 mbar / ± 1 % + 0.01 mbar

 ± 0.6 PSI / 0.0001 PSI / ± 1 % + 0.0001 PSI
Air Velocity
Range/Resolution/Accuracy  250 to 16,000 fpm / 1 fpm / ± 2.5 % of reading at 2000 fpm (10.00 m/s)

 1 to 80 m/s / 0.001 m/s / ± 2.5 % of reading at 2000 fpm (10.00 m/s)
Air Flow (Volume)
Range/Resolution/Accuracy  0 to 99,999 cfm / 1 cfm / Accuracy is a function of velocity and duct size

 0 to 99,999 / 1 m3/hr / Accuracy is a function of velocity and duct size

 0 to 99,999 l/s / 1 l/s / Accuracy is a function of velocity and duct size
Temperature
Range/Resolution/Accuracy  0 °C to 50 °C / ± 1 % + 2 °C / 0.1 °C

 32 °F to 122 °F / ± 1 % + 4 °F / 0.1 °F
General Specifications
Operating Temperature

 0 °C to +50 °C (+32 °F to +122 °F)
Storage Temperature

 -40 °C to +60 °C (-40 °F to +140 °F)
Relative Humidity

 0% to 90%, non-condensing
IP Rating

 IP40
Operating Altitude

 2000 m
Storage Altitude

 12000 m
EMI, RFI, EMC

 Meets requirements for EN61326-1
Vibration

 MIL-PREF-28800F, Class 3
Max Pressure at Each Port

 10 PSI
Data storage capacity

 99 readings
Power, battery life

 Four AA batteries
Battery Life

 280 hours without backlight, 60 hours with backlight



Pemesanan Dan Informasi Hub. Harytan