Senin, 29 Desember 2014

METERAN LASER DIGITAL FLUKE 414D - 50 METER , AKURAT, CEPAT DAN SIMPLE

LASER DISTANCE METER FLUKE 414D - 081806120636 - 2975C3A4
The 414D reduces errors, saves time, saves money.
Features:

The most advanced laser technology for distance measurement
Simple one-button operation to instantly measure distance between two objects
Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in)
Bright laser for easy targeting even at longer distances
Quick calculation of area (square feet/meters) and volume
Easy addition and subtraction function
Pythagoras function indirectly measures height via two other measurements
Stores up to five measurement results
Battery life of 3000 measurements with automatic shut-off feature
Two-line display with display hold (until next button is pressed)
Carrying pouch secures to your tool belt
Powered by two AAA batteries

All meters offer:

Reduction of estimation errors, saving both time and money
The most advanced 2 laser technology for distance measurement
Instant measurement with one-button operation
Easy addition and subtraction function
Quick calculation of area (square footage) and volume
Easy addition and subtraction of measurements
Minimum/maximum function
Improved battery life from automatic shut-off feature
Pythagoras calculation for determining distance indirectly from two other measurements
Pouch with Fluke logo
Three-year warranty


Laser Distance Meter
Includes:

414D Laser Distance Meter
Two AAA batteries
Users manual on CD (17 languages)
Quick reference guide
Vinyl carrying pouch

(Fluke 414D Laser Distance Meter ( indoor/ outdoor, 50m) Call. 081806120636/ Hary

Fitur:
* teknologi laser terbaru untuk pengukuran jarak
* Pengoperasian sederhana satu tombol secara instan mengukur jarak antara dua obyek
* Mengukur hingga 50 m dengan tingkat akurasi 2 mm
* Sinar laser yang terang untuk membidik dengan mudah bahkan pada jarak yang jauh
* Kalkulasi area dengan cepat ( square feet/ meter) dan volume
* Fungsi penjumlahan dan pengurangan yang mudah
* Fungsi Pythagoras secara tidak langsung mengukur tinggi lewat dua pengukuran lainnya
* Menyimpan hingga lima hasil pengukuran
* Usia baterai hingga 3000 kali pengukuran dengan fitur shut-off otomatis
* Tampilan display 2-baris dengan fungsi hold ( sampai tombol ditekan lagi)
* Tas pinggang yang aman pada sabuk
* Dihidupkan dengan dua buah baterai AAA) Untuk Pemesanan Dan Informasi Hub. Harytan 02.71601997 , 081806120636 , 2975C3A4 , Email : alatsurveykita61@gmail.com


Kamis, 26 Juni 2014

Fluke 971 Temperature Humidity Meter - 081806120636

Fluke 971 Temperature Humidity Meter  - 081806120636



Specifications
Temperature

 -20°C to 60°C (-4°F to 140°F)
Temperature accuracy

 0°C to 45°C (±0.5°C)

 -20°C to 0°C & 45°C to 60°C (±1.0°C)

 32°F to 113°F (±1.0°F)

 -4°F to 32°F & 113°F to 140°F (±2.0°F)
Resolution

 0.1°C / 0.1°F
Temperature Update Rate

 500 ms
Temperature Sensor Type

 NTC
Relative Humidity Range

 5% to 95% RH
Relative Humidity Accuracy

 10% to 90%RH @ 23 °C (73.4°F) (±2.5%RH)

 (<10%, > 90%RH @23°C (73.4°F) (±5.0%RH)
Humidity Sensor

 Electronic capacitance polymer film sensor.
Data storage capacity

 99 points
Response Time (Humidity)

 For 90% of total range - 60 sec. with 1m/s air movement
Environmental Specifications
Operating Temperature

 Temperature: -20°C to 60°C

 Humidity: 0°C to 55°C
Storage Temperature

 -20°C to 60°C at < 80% R.H. (with battery removed)
Mechanical & General Specifications
Weight

 190 g (6.7 oz)
Dimensions

 194mm x 60mm x 34mm
Battery type

 4 AAA alkaline batteries
Battery Life

 200 Hours

Fluke 922 Airflow Meter/Micromanometer - 081806120636 - 021.71601997

Fluke 922 Airflow Meter/Micromanometer - 081806120636 - 021.71601997
Technical Specifications
Air Pressure
Range/Resolution/Accuracy  ± 4000 Pascals / 1 Pascal / ± 1 % + 1 Pascal

 ± 16 in H2O / 0.001 in H2O / ± 1 % + 0.01 in H2O

 ± 400 mm H2O / 0.1 mm H2O / ± 1 % + 0.1 mm H2O

 ± 40 mbar / 0.01 mbar / ± 1 % + 0.01 mbar

 ± 0.6 PSI / 0.0001 PSI / ± 1 % + 0.0001 PSI
Air Velocity
Range/Resolution/Accuracy  250 to 16,000 fpm / 1 fpm / ± 2.5 % of reading at 2000 fpm (10.00 m/s)

 1 to 80 m/s / 0.001 m/s / ± 2.5 % of reading at 2000 fpm (10.00 m/s)
Air Flow (Volume)
Range/Resolution/Accuracy  0 to 99,999 cfm / 1 cfm / Accuracy is a function of velocity and duct size

 0 to 99,999 / 1 m3/hr / Accuracy is a function of velocity and duct size

 0 to 99,999 l/s / 1 l/s / Accuracy is a function of velocity and duct size
Temperature
Range/Resolution/Accuracy  0 °C to 50 °C / ± 1 % + 2 °C / 0.1 °C

 32 °F to 122 °F / ± 1 % + 4 °F / 0.1 °F
General Specifications
Operating Temperature

 0 °C to +50 °C (+32 °F to +122 °F)
Storage Temperature

 -40 °C to +60 °C (-40 °F to +140 °F)
Relative Humidity

 0% to 90%, non-condensing
IP Rating

 IP40
Operating Altitude

 2000 m
Storage Altitude

 12000 m
EMI, RFI, EMC

 Meets requirements for EN61326-1
Vibration

 MIL-PREF-28800F, Class 3
Max Pressure at Each Port

 10 PSI
Data storage capacity

 99 readings
Power, battery life

 Four AA batteries
Battery Life

 280 hours without backlight, 60 hours with backlight



Pemesanan Dan Informasi Hub. Harytan
021.71601997 - 0810806120636 - Pin.2975C3A4
Email.alatsurveykita61@gmail.com


Fluke 116 HVAC Multimeter with Temperature and Microamps - 081806120636

Fluke 116 HVAC Multimeter with Temperature and Microamps  - 081806120636
Specifications
Maximum voltage between any terminal and earth ground

 600 V
Surge protection

 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital:  6,000 counts, updates 4 per second
Bar graph

 33 segments, updates 32 per second
Operating Temperature

 -10 °C to + 50 °C
Storage Temperature

 -40 °C to + 60 °C
Battery type

 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life

 400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:  600.0 V
Resolution:  0.1 V
Accuracy:  2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  1.5 % + 2
Diode Test
Range/Resolution:  2.000 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 μF / 0.01 μF
Range/Resolution:  100.0 μF / 0.1 μF
Range/Resolution:  9999 μF / 1 μF
Range/Resolution:  100 μF to 1000 μF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 μF
Accuracy:  5% + 20%
LoZ capacitance
Range:  1 nF to 500 μF
Accuracy:  10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution:  -40 °C to 400 °C / 0.1 °C
Accuracy:  1% + 102
Range/Resolution:  -40 °F to 752 °F / 0.2 °F
Accuracy:  1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution:  600.0 μA / 0.1 μA
Accuracy:  1.0% + 2
DC μamps
Range/Resolution:  600.0 μA / 0.1 μA
Accuracy:  1.0% + 2
Hz (V or A input)2
Range/Resolution:  99.99 Hz / 0.01 Hz
Range/Resolution:  999.99 Hz / 0.1 Hz
Range/Resolution:  9.999 Hz / 0.001 Hz
Range/Resolution:  50.00 Hz / 0.01 Hz
Accuracy:  0.1% + 2
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

Mechanical & General Specifications
Size

 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight

 550 g
Pemesanan dan Informasi
Hub. Harytan  : 021.71601997 - 081806120636 - 2975C3A4
Fax.021.71601997 - Email.alatsurveykita61@gmail.com



Fluke 2042 Cable locator - 081806120636 - 021.71601997

Fluke 2042 Cable locator- 081806120636 - 2975C3A4 - Fax.021.7318012

Technical Specifications
Voltage measurement range
Transmitter:  12 V, 50 V, 120 V, 230 V, 400 V
Frequency range
Transmitter:  0...60 Hz
Output signal
Transmitter:  125 kHz
Voltage
Transmitter:  Up to 400 V AC/DC
Tracing depth cable location
Receiver:  0...2.5 m wall/underground cables
Main voltage detection
Receiver:  0...0.4 m
Environmental Specifications
Operating Temperature
Transmitter:  0 to 40°C
Receiver:  0 to 40°C
Storage Temperature
Transmitter:  -20°C to +60°C
Receiver:  -20°C to +60°C
Humidity (Without Condensation)
Transmitter:  Max. 80% relative
Receiver:  Max. 80% relative
Operating Altitude
Transmitter:  Up to 2000 m
Receiver:  Up to 2000 m
Safety Specifications
Electrical Safety

 EN 61010-1
Overvoltage category

 Cat. III 300 V
Mechanical & General Specifications
Size
Transmitter:  190 mm x 85 mm x 50 mm
Receiver:  250 mm x 65 mm x 45mm
Weight
Transmitter:  0.45 kg
Receiver:  0.36 kg
Batteries
Transmitter:  6 pc Batteries 1.5V
Receiver:  1 pc Battery 9V

Cable Locator

  • 4 test leads
  • battery 9 V, IEC 6LR61
  • 6 batteries 1.5 V, IEC LR^6
  • 2 crocodile clamps
  • 2 test probes
  • carrying case
  • user manual

Pemesanan Dan Informasi Hub. Harytan                   081806120636 - 021.71601997 - 2975C3A4  -  Fax.021.7318012 - Email. alatsurveykita61@gmail.com





Fluke 1AC-II / 1LAC-II VoltAlert - 081806120636 - 021.71601997

Fluke 1AC-II / 1LAC-II VoltAlert - 081806120636 - 021.71601997


  • Voltbeat™ technology and continuous self-test — so you always know it’s working
  • Upon detection, tip glows and beeper sounds
  • CAT IV 1000 V for added protection
  • Expanded range: 90 V to 1000 V AC or 200 V to 1000 V AC depending on model
  • 20 V to 90 V AC control circuit model also available

  • Pemesanan Dan Informasi Hub. Harytan
    021.71601997 - 081806120636 - 2975C3A4
    Fax.021.7318012 - email. alatsurveykita61@gmail.com


    Fluke 9062 Motor & Phase Rotation Indicator - 081806120636 - 021.71601997

    Fluke 9062 Motor & Phase Rotation Indicator - 081806120636 - 021.71601997
    Technical Specifications
    Voltage range

     Up to 400 V
    Phase Display

     120-400 V AC
    Frequency range

     2-400 Hz
    Operating timer

     Continuous
    Environmental Specifications
    Operating temperature

     0 °C to 40 °C
    Operating Altitude

     Up to 2000m
    Humidity (Without Condensation)

     15 % to 80 %
    Dust/water resistance

     IP 40
    Safety Specifications
    Electrical Safety

     EN 61010,

     EN 61557-7
    Overvoltage category

     CAT III, 300 V
    Mechanical & General Specifications
    Size

     124 x 61 x 27 mm
    Weight

     1 x 9 V
    Batteries

     1 x 9 V


    Pemesanan Dan Informasi Hub. Harytan
    021.71601997 - 081806120636 - Pin.2975C3A4
    Fax.021.7318012 - Email.alatsurveykita61@gmail.com

    Fluke 9040 Phase Rotation Indicator 021.71601997 - 081806120636

    Fluke 9040 Phase Rotation Indicator  021.71601997 - 081806120636
    Technical Specifications
    Voltage range

     40-700 V
    Frequency range

     15-400 Hz
    Operating timer

     Continuous
    Environmental Specifications
    Operating temperature

     0 °C to 40 °C
    Dust/water resistance

     IP 40
    Safety Specifications
    Electrical Safety

     EN 61010,

     EN 61557-7
    Overvoltage category

     CAT III, 600 V

     CAT IV, 300V
    Mechanical & General Specifications
    Size

     124 x 61 x 27 mm
    Weight

     200 g
    Power supply

     From unit under test
    Pemesanan dan Informasi Hub. Harytan
    021.71601997 - 081806120636 -Pin.2975C3A4
    Fax.021.7318012 , Email.: alatsurveykita61@gmail.com

    Fluke 114 Electrical Multimeter -021.71601997 - 081806120636

    Specifications
    Maximum voltage between any terminal and earth ground

     600 V
    Surge protection

     6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
    Display
    Digital:  6,000 counts, updates 4 per second
    Bar graph

     33 segments, updates 32 per second
    Operating Temperature

     -10 °C to + 50 °C
    Storage Temperature

     -40 °C to + 60 °C
    Battery type

     9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery Life

     400 hours typical, without backlight
    Accuracy Specifications
    DC millivolts
    Range:  600.0 mV
    Resolution:  0.1 mV
    Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
    DC volts
    Range/Resolution:  6.000 V / 0.001 V
    Range/Resolution:  60.00 V / 0.01 V
    Range/Resolution:  600.00 V / 0.1 V
    Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
    Auto volts
    Range:  600.0 V
    Resolution:  0.1 V
    Accuracy:  2.0 % + 3 (dc, 45 Hz to 500 Hz)4.0 % + 3 (500 Hz to 1 kHz)
    AC millivolts1 true-rms
    Range:  600.0 mV
    Resolution:  0.1 mV
    Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
    AC volts1 true-rms
    Range/Resolution:  6.000 V / 0.001 V
    Range/Resolution:  60.00 V / 0.01 V
    Range/Resolution:  600.0 V / 0.1 V
    Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
    Continuity
    Range:  600 Ω
    Resolution:  1 Ω
    Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
    Ohms
    Range/Resolution:  600.0 Ω / 0.1 Ω
    Range/Resolution:  6.000 kΩ / 0.001 kΩ
    Range/Resolution:  60.00 kΩ / 0.01 kΩ
    Range/Resolution:  600.0 kΩ / 0.1 kΩ
    Range/Resolution:  6.000 MΩ / 0.001 MΩ
    Accuracy:  0.9 % + 1
    Range/Resolution:  40.00 MΩ / 0.01 MΩ
    Accuracy:  5 % + 2
    Notes:
    1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
    2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
    3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
    4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

    Mechanical & General Specifications
    Size

     167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
    Weight

     550 g

    Senin, 23 Juni 2014

    Fluke 1630 Earth Ground Clamp Meter - 081806120636 - 2975C3A4 -021.71601997

    Fluke 1630 Earth Ground Clamp Meter  - 081806120636 - 2975C3A4 -021.71601997


    General Specifications
    Operating error

     Refers to the operating temperature range and is guaranteed for 2 years
    Storage temp. range

     -20 °C to 60 °C (-4°F to 140 °F)
    Reference temp. range

     23 °C ± 5 °C (73 °F ± 9 °F)
    Storage humidity

     <75 % Rh
    Operating humidity

     <85% Rh
    Display

     999 digital LC display with special symbols
    Protection

     IP30 according to IEC 529/EN 60529
    Safety

     300 V, CAT III pollution degree 2 IEC 61010-1 and IEC 61010-2-032
    Weight

     750 g (1.165 lbs)
    Conductor size

     35 mm (1.38 in) approximately
    Dimension (length x width x depth)

     276 mm x 100 mm x 47 mm (10.8 in x 3.9 in x 1.9 in)
    Emission

     IEC 1000 4-2, IEC 61326-I class B
    Immunity

     IEC 61000-4-2, 8 kV (air) criteria A

     IEC 61000-4-3, 3 V/m performance criteria A
    Range selection

     Auto
    Overload indicator

     "OL" on display
    Measuring time

     0.5 sec
    Measuring frequency

     3.333 kHz
    Battery type

     9 V alkaline (type IEC 6 LR 61)
    Battery life

     ≥ 8 hours (continuous operation)
    Power consumption

     40 mA
    Low battery indication

     Display symbol
    Ground Loop Resistance (Autorange)
    Range

     Accuracy
    (± % of reading Ω)
    0.025 - 0.250 Ω

     ± 1.5 % rdg ± 0.02 Ω
    0.250 - 9.999 Ω

     ± 1.5 % rdg ± 0.05 Ω
    10.00 - 99.99 Ω

     ± 2.0 % rdg ± 0.3 Ω
    100.0 - 199.9 Ω

     ± 3.0 % rdg ± 1.0 Ω
    200.0 - 400.0 Ω

     ± 5.0 % rdg ± 5 Ω
    400.0 - 600.0 Ω

     ± 10 % rdg ± 10 Ω
    600.0 - 1500 Ω

     ± 20 %
    Note:

     Loop resistance with no inductance, external magnetic field < 50A/m, external electrical field < 1 V/m, conductor centered.

    Fluke 1621 Earth Ground Tester - 021.71601997 - 081806120636

    Fluke 1621 Earth Ground Tester -  021.71601997 - 081806120636
    The Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.


     

































































































































































































































































































































































































































































































































































































    Measuring functions

     3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage
    Intrinsic error

     Refers to the reference temperature range and is guaranteed for one year
    Measuring rate

     2 measurements/second
    Battery[1]

     One 9 volt alkaline (LR61)
    Battery condition

     LO-BAT is displayed if voltage drops below 6.5 V
    Voltages
    Between jacks H/C2 and E/C1:  250 Veff maximum (effective voltage)
    Between jacks S/P2 and E/C1:  250 Veff maximum
    Climatic class

     VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87)
    Temperature performance[2]
    Working:  -10 °C to +50 °C (+14 °F to +122 °F)
    Operating:  0 °C to +35 °C (+32 °F to +95 °F)
    Storage:  -20 °C to +60 °C (+68 °F to +140 °F)
    Reference:  +23 °C ± 2 °C (+73 °F ± 4 °F)
    Temperature coefficient

     ± 0.1 % of range per degree Kelvin
    Safety

     IEC/EN 61010-1, 600 V CAT II, pollution degree 2
    Dimensions

     113 mm x 54 mm x 216 mm (4.5 in x 2.1 in x 8.5 in), including holster
    Weight

     850 g (1.9 lb), including standard accessories, volume approximately 600 cm3
    Note:

     [1]If the tester is not going to be used, or is being stored for a long period, remove the battery and store separately from the tester to avoid damage from battery leakage.
    Note:

     [2]The four temperature ranges for the tester exists to satisfy European Standards requirements; the instrument can be used over the full working temperature range by using the temperature coefficient to calculate accuracy at the ambient temperature of use.
    Electrical specifications
    Maximum deviations:
    E1 Influence factor  Position
    E1 Deviation influence  0 %
    E2 Influence factor  Supply voltage
    E2 Deviation influence  0 %
    E3 Influence factor  Temperature E3
    E3 Deviation influence  2.3 %
    E4 Influence factor  Serial interference voltage (20 V)
    E4 Deviation influence  0.6 %
    E5 Influence factor  Probe- and auxiliary probe resistance
    E5 Deviation influence  10 %
    Test voltage

     3.7 kV
    Protection type

     IP 40; IEC/EN 60529
    Electromagnetic compatibility

     Emission: IEC/EN 61326 Class B

     Immunity: IEC/EN 61326 Annex C
    RE resistance measurement
    Measuring method  Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557-5
    Open circuit voltage  23 to 24 V ac
    Short circuit current  > 50 mA ac
    Measuring frequency  128 Hz
    Maximum permissible overload  250 Veff
    Measuring time

     8 seconds (average from when START is pressed)
    Limit input

     Tester retains set value even if instrument is turned off (assuming battery power supply is sufficient)
    Automatic changeover of resolution
    RH  < 7 kΩ
    Resolution  0.01 Ω
    RH  < 50 kΩ
    Resolution  0.1 Ω
    RH  > 50 kΩ
    Resolution  1 Ω
    Interference voltage display dc + ac
    Vmax  30 Veff
    Common mode rejection  > 80 dB at 50 Hz and 60 Hz
    Ri  680 kΩ
    Measuring uncertainty  < 10 % for pure ac and dc signals
    Measuring range
    0.15 Ω to 20 Ω
    Resolution  0.01 Ω
    Display range  0 to 19.99 Ω
    200 Ω
    Resolution  0.1 Ω
    Display range  20 to 199.9 Ω
    2 kΩ
    Resolution  1 Ω
    Display range  200 to 1999 Ω
    Intrinsic uncertainty

     ± (6 % of measured value + 5D)
    Operating uncertainty IEC 61557[1]

     ± (18 % of measured value + 5D)
    Notes:

     [1] Covers all deviations caused by influence quantities E1-E5.
    If the deviation E4 caused by high probe or auxiliary probe resistance is higher than specified flashes.
    Measured values are outside of the specified operating uncertainty.